2000 PSI/14 MPa RECYCLING VERTICAL CYCLONE TEST SEPARATOR
Maximum Operating Pressure (limited to PSV set pressure) - 2000 psig (13.79 MPag)
Pressure Relief Valve Maximum Flow Rate - 47.9 MMscf/d (1,349.5 E3m3/d)
Maximum System Gas Flow Rate at 90% M.A.W.P. - 43.11 MMscf/d (1,214.6 E3m3/d)
Fluids Retention Time to Obtain Separation - 5minutes
Maximum Vessel Liquid Storage Capacity - 1.46 bbl (0.23 m3)
Maximum Vessel Liquid Rate Operating at 50% Capacity - 1,200 bbl/d (191 m3/d)
Maximum Vessel Operating Temperature at Maximum Pressure - 100°F (38°C)
Minimum Vessel Operating Temperature at Maximum Pressure - -16°F (-27°C)

DSCF0773UNIT DIMENSIONS

Width -8.0 ft (2.4 m)
Length32 ft (9.75 m)
Height - 13 ft 8 in (4.2 m)
Weight Estimate - 35,200 lbs (16,000 kg)

FLUID TRANSFER SIZE & PRESSURE RATING

Fluid Inlet Size3 inch (76.2 mm)
Inlet M.A.W.P.2,000 psig (13,789 kPa)
Gas Outlet Size3 inch (76.2 mm)
Oil Outlet Size2 inch (50.8 mm)
Water Outlet Size - 2 inch (50.8 mm)

FLOW INSTRUMENTATION

EFM Data Aquisition System
Meter Run Senior Daniel's 4 inch (101.6 mm)
Liquid Turbines 1 inch (25.4 mm)

APPROVAL & CERTIFICATIONS

Sour Service NACE Standard MR0175/ISO15156
Vessel - ASME Section VIII Div. 1
Piping - ASME B31.3
Alberta Boiler Safety Association